Features
Vector AC Variable Frequency Drive: Introduction
3AC 380~415V, 0.75~1.5kW
Mini size variable frequency drive
Best cost-effective product
Compact structure
Easy installation, easy parameters setting
V/f and Sensorless Vector Control(SVC)
Suitable for small power applications
Vector AC Variable Frequency Drive: Features
|
No. |
Items |
D100 |
|
1 |
Reliable hardware |
Only first-class componens are built-in. |
|
2 |
Rubust design |
All the components are selected at higher size. |
|
3 |
PCB aging test |
100% test, 45°C, 12 hours. |
|
4 |
Finished products aging test |
100% test, 50°C, 24 hours. |
|
5 |
Loading test |
Two times, 100%:
1. After manufacturing.
2. After aging test.
|
|
6 |
Grouped pulse testing |
Without failure under 4500V (better EMC performance). |
|
7 |
Electrostatic testing |
1. Noncontact conditions -- without failure under 10000V.
2. Under contact condition -- without failure under 5000V.
|
|
8 |
Unqualification during production |
<0.03% |
|
9 |
Total failure ratio at industrail sites |
<0.5% |
|
10 |
High overload capacity |
150% / 60s, 180% / 10s, 200% /1s |
|
11 |
Smart start / stop mode |
Acceleration / Deceleration time can be set as 0.0s, the inverter start and stop the motor as fast as possible without failure. |
|
12 |
S ccure Acceleration / Deceleration mode |
Better start stop performance. |
|
13 |
Big start torque |
0.5Hz/150% (V/f), 1Hz/150% (SVC) |
|
14 |
Better stop performance |
1. Current is limited smoothly while stoping;
2. Stops smoothly in very short time for heavy load applications.
|
|
15 |
Better input voltage flexibility |
-15%~+15% without failure. |
Vector AC Variable Frequency Drive: Features
|
No. |
Items |
D100 |
|
1 |
Reliable hardware |
Only first-class componens are built-in. |
|
2 |
Rubust design |
All the components are selected at higher size. |
|
3 |
PCB aging test |
100% test, 45°C, 12 hours. |
|
4 |
Finished products aging test |
100% test, 50°C, 24 hours. |
|
5 |
Loading test |
Two times, 100%:
1. After manufacturing.
2. After aging test.
|
|
6 |
Grouped pulse testing |
Without failure under 4500V (better EMC performance). |
|
7 |
Electrostatic testing |
1. Noncontact conditions -- without failure under 10000V.
2. Under contact condition -- without failure under 5000V.
|
|
8 |
Unqualification during production |
<0.03% |
|
9 |
Total failure ratio at industrail sites |
<0.5% |
|
10 |
High overload capacity |
150% / 60s, 180% / 10s, 200% /1s |
|
11 |
Smart start / stop mode |
Acceleration / Deceleration time can be set as 0.0s, the inverter start and stop the motor as fast as possible without failure. |
|
12 |
S ccure Acceleration / Deceleration mode |
Better start stop performance. |
|
13 |
Big start torque |
0.5Hz/150% (V/f), 1Hz/150% (SVC) |
|
14 |
Better stop performance |
1. Current is limited smoothly while stoping;
2. Stops smoothly in very short time for heavy load applications.
|
|
15 |
Better input voltage flexibility |
-15%~+15% without failure. |
Vector AC Variable Frequency Drive :Selection
|
Inverter Model |
Motor |
Rated Input Current (A) |
Rated Output Current (A) |
|
|
kW |
HP |
|||
|
3AC 380V±15% |
||||
|
D100-00075T4 |
0.75 |
1 |
3.4 |
2.5 |
|
D100-00150T4 |
1.5 |
2 |
5.0 |
4.2 |